6 research outputs found

    Rotating Scheimpflug Imaging Indices in Different Grades of Keratoconus

    Get PDF
    Purpose. To evaluate accuracy of various Keratoconus (KC) screening indices, in relation to Topographic Keratoconus (TKC) grading. Setting. Al Watany Eye Hospital, Cairo, Egypt. Methods. Data of 103 normal (group 1) and 73 KC eyes (group 2), imaged by Pentacam (branded as Allegro Oculyzer), were analysed. Group 2 was divided into 2a: 14 eyes (TKC = 1, early KC), 2b: 25 eyes (TKC = 1 to 2 or 2, moderate KC), and 2c: 34 eyes (TKC = 2 to 3 up to 4, severe KC). Participants were followed up for six years to confirm diagnosis. Area under the receiver operating characteristic curve (AUROC) was calculated for evaluated curvature, elevation, and pachymetry indices with various reference shapes at different diameters. Results. When comparing normal to KC eyes, ten indices had significantly higher AUROC. Only five of them had significantly higher AUROC in early KC compared to normal corneas: Pachymetry Progression Index- (PPI-) Maximum (Max), Ambrósio’s Relational Thickness- (ART-) Max, PPI-Max minus PPI-Minimum (Min), central corneal thickness (CCT), and diagonal decentration of thinnest point from the apex (AUROC = 0.690, 0.690, 0.687, 0.683, and 0.674, resp.). Conclusion. Generally, ten pachymetry and elevation-based indices had significantly higher AUROC. Five indices had statistically significant high AUROC when comparing early KC to normal corneas

    Effectiveness of Green Roofs and Green Walls on Energy Consumption and Indoor Comfort in Arid Climates

    Get PDF
    Increased urbanization have many negative effects on human well-being, city infrastructure, electricity usage and the increase of indoor temperatures. A solution may be to retrofit existing buildings, with implementing a vegetated layer to roofs and walls, this may enhance building performance, reduce consumption and improve indoor comfort. Cities with tall buildings may be more adequate to implement a green-wall as it have more area to make impact. This paper examines the energy reduction advantages of adding greenery on buildings in the hot arid climate of Egypt by considering three typical types of residential buildings in the city of Cairo as a case study. Designbuilder software was selected to stimulate the buildings chosen in this research. The results shows that an extensive soil thickness of 15cm performs better in the arid climates. electricity consumption for the base case is 52 kWh/m2 annually when used a traditional external envelop and dropped to 43 kWh/m2 when a vegetated layer added to the whole building (roof & wall), annual electricity consumption reduced by 17% to 25% per annum when added a vegetated layer. In addition to enhancing the indoor thermal comfort by 3 PMV values and indoor air temperature by 5°C

    Cap-preserving SMILE Enhancement Surgery

    No full text
    Abstract Background Different enhancement procedures have been suggested for reduction of residual refractive errors after SMILE. The aim of this study is to evaluate an improved cap-preserving technique for enhancement after SMILE (Re-SMILE). Methods A retrospective case series was conducted at Eye subspecialty center, Cairo, Egypt on 9 eyes with myopia or myopic astigmatism (spherical equivalent – 8.0 and − 12.0D). undergoing SMILE procedure and needed second interference. This was either because the more myopic meridian was more than − 10.0 D and therefore planned to have two-steps procedure (six eyes) or because of under correction needing enhancement (three eyes). Assessment after the primary SMILE procedure was conducted at 1 day, 1 week, 1 month and 3 months postoperatively. Assessment after Re-SMILE was conducted at 1 day, 1 week, 1 month, 3 months, 6 months and 1 year postoperatively. The assessments included full ophthalmic examination, objective and subjective refraction, and rotating Scheimpflug camera imaging. Results Preoperatively, the mean refractive spherical equivalent (MRSE) values were: − 9.36 ± 0. 89. After primary SMILE it was − 2.18 ± 0.71. After Re-SMILE it was − 0.13 ± 0.68. MRSE was significantly improved after both procedures (P < 0.01). The safety index of primary SMILE cases was 1.65 ± 0.62 and for Re-SMILE 1.13 ± 0.34 and the efficacy index was 1.14 ± 0.24 after primary SMILE and 1.11 ± 0.26 after Re-SMILE. Conclusion Centered cap-preserving Re-SMILE is an effective procedure in reducing residual refractive errors after primary SMILE in high myopes

    Topographic Asymmetry Indices: Correlation between Inferior Minus Superior Value and Index of Height Decentration

    No full text
    Purpose. To investigate the correlation between decentration index (index of height decentration, IHD) automatically calculated by the Pentacam HR software and the manually calculated inferior minus superior (I‐S) value. Setting. Al Watany Eye Hospital, Cairo, Egypt. Methods. In a retrospective study, history taking, clinical examination, and rotating Scheimpflug camera scanning (by Oculyzer II equivalent to Pentacam HR) were done to 128 eyes: 82 normal, 24 forme fruste keratoconus FFKC (apparently normal cornea with evident keratoconus in the fellow eye), and 22 keratoconus (KC). All cases of corneal scars or previous corneal surgeries were excluded. The (I‐S) value was calculated manually from 10 points astride the horizontal meridian. The IHD is calculated automatically by the device software 1.17r119. Results. The mean (±SD) of (I‐S) value in normal, FFKC, and KC eyes were 0.30 ± 0.93, 0.11 ± 2.03, and 4.62 ± 3.89, respectively, and those of IHD were 0.008 ± 0.004, 0.011 ± 0.005, 0.066 ± 0.067, respectively. The two indices were highly correlated (p<0.0001) with a correlation coefficient (r2 = 0.874). Deduced regression formulae linking the two indices were calculated. Conclusions. The two topographic decentration indices are highly correlated. Deduced formulae were proposed linking them
    corecore